GYPSEA BLEU LIVEABOARD TOOL

Battery Charging & Generator Runtime Calculator

Estimate how much energy your battery bank needs, how much solar and alternator charging will contribute, and how long the generator must run to reach your target state of charge.

Planning aid only. Actual charging power can be limited by battery BMS settings, charger programming, alternator temperature, battery temperature, wiring, charge acceptance, taper near full charge, generator loading, and other onboard loads. Follow battery, charger, alternator, and generator manufacturer limits.

Battery Bank

Enter your battery size and charging sources. The calculator treats each source as energy delivered to the battery after the efficiencies you enter.

Battery bank
Solar contribution
Alternator contribution
Shore / other charger contribution
Generator & charger

Saved automatically on this device.

Your Charging Plan

48 V · 600 Ah · 35% → 90%

Battery bank28.8 kWhnominal stored-energy capacity
Energy needed15.8 kWhfrom current SOC to target SOC
Generator runtime0.0 hrafter planned solar, alternator & other charging
Generator fuel0.0 gal$0 estimated fuel cost

Energy Contributions

Solar delivered0 kWh
Alternator delivered0 kWh
Other charger delivered0 kWh
Remaining before generator0 kWh
Generator net charging power0 kW
Generator-only runtime0 hr
Estimated SOC without generator0%
Your planned non-generator charging reaches the target SOC.

Generator Charger Comparison

Estimated runtime from the current SOC to target SOC with no solar, alternator, or shore contribution. House load, charge efficiency, taper factor, and runtime margin remain applied.

Planning Details

Current stored energy0 kWh
Target stored energy0 kWh
Effective generator charger current0 A
Generator runtime margin applied0%

Planning Notes

  • Battery capacity is calculated from nominal voltage × amp-hours. Real usable energy can differ from the nameplate value.
  • The acceptance/taper factor reduces average charging power to reflect that batteries often do not accept full charger output throughout the entire charge cycle.
  • Generator house loads are subtracted from the charger’s effective DC charging power before runtime is calculated.
  • Alternator thermal derating can be significant during long charging sessions. Enter a conservative current that reflects sustainable output.
  • Do not exceed battery BMS, cell, charger, alternator, cabling, fuse, or manufacturer charge-current limits.