Marine Electrical Load Audit: A Practical Guide
Open the Marine Electrical Load Audit →
Worked example: daily energy use
Suppose a 12 V boat runs a 60 W refrigerator for an equivalent of 10 hours per day (600 Wh), 20 W of lights for 4 hours (80 Wh), and a 45 W laptop for 3 hours (135 Wh). Together they consume 815 Wh per day before conversion losses, pumps, instruments, and reserve. At 12 V nominal, 815 Wh is about 68 Ah. If the laptop uses an inverter, allow for its measured efficiency as well.
FAQ: Does the audit determine battery size? No. It estimates usage. Battery sizing also depends on usable depth of discharge, autonomy days, voltage, charging availability, and reserve. Next, use the Marine Solar & Battery Sizing Calculator to plan capacity.
Why conduct a load audit?
Battery and solar systems should be sized from actual energy use rather than guesses. The audit adds each electrical appliance’s watts, hours of operation and quantity, distinguishing appliances operating on battery DC from appliances powered through an inverter. For AC appliances, inverter efficiency accounts for additional power drawn from the batteries.
Watts, watt-hours and amp-hours
Watts represent instantaneous power. Watt-hours represent energy: W × hours = Wh. Nominal amp-hours can be estimated as watt-hours ÷ battery voltage, but this does not replace energy modeling at real operating voltage. For example, a 50W compressor that runs for eight total hours daily uses about 400Wh/day, not 1,200Wh/day.
How to complete the audit
- Select the nominal 12V, 24V or 48V bank voltage.
- Choose a realistic inverter efficiency and reserve allowance.
- Choose desired battery-only days of autonomy and the battery’s estimated usable fraction.
- Enter each device, select AC or DC, enter running watts, daily active hours, and number of units.
- Use Add Device for additional rows; the calculator updates totals as values change.
- Review the resulting Wh/day, Ah/day and illustrative battery energy target.
Common cruising loads to include
Refrigerators and freezers, autopilot, plotter, radar, AIS, instruments, VHF, satellite communications, Starlink, cabin fans, water pressure pumps, lighting, laptops, chargers, watermakers, and galley appliances. Include the inverter’s idle use as a separate load if appropriate. Measure duty cycles: refrigerators may run 6–16 equivalent hours depending on climate and installation, not automatically 24 hours.
Worked example
A 45W refrigerator operating 12 equivalent hours consumes 540Wh. Navigation electronics at 35W for 10 hours consume 350Wh. Starlink at 65W for eight hours consumes 520Wh. Two 100W laptop loads used three hours consume 600Wh AC, equivalent to approximately 667Wh from the bank at 90% inverter efficiency. Lighting at 20W for five hours consumes 100Wh. Total estimated bank demand is about 2,177Wh/day before reserves.
Captain’s Note — Test the boat in real conditions
Measure actual consumption over several days at anchor, on passage and in hot weather. Refrigerator duty cycle, autopilot activity, watermaker use and satellite internet may change significantly. A shunt monitor helps reconcile calculated energy use with observed battery draw.
What the result doesn’t cover
A daily energy audit does not by itself size an inverter’s maximum continuous or motor-start surge requirement, decide DC cable gauge, account for charge-controller output, model solar weather variability or guarantee battery runtime. Use the related Inverter Sizing, Solar & Battery Sizing, Battery Charging & Generator, and Marine Wire Size tools for those separate planning steps.
Safety: This is an educational energy estimate. Marine electrical design and changes should be verified against manufacturer guidance and the applicable ABYC standards.